Search results for "High Dose Rate"

showing 3 items of 3 documents

Could alanine/EPR dosimetry be useful for ultra-high dose rate beams used for FLASH radiotherapy?

In the last years a large interest has aroused towards radiation therapy treatments with dose rates much larger with respect to the conventional ones since experiments support the evidence of a considerable normal tissue sparing effect. Indeed, in-vivo experiments showed an increasing of the therapeutic window for dose rates over 50 Gy/s [2]. If confirmed, the ‘FLASH effect’ has the potential to re-shape the future of radiation treatments, with a significant impact on many oncology patients. Significant dosimetric challenges should be dealt with for Ultra-high dose rate (UHDR) beams for FLASH radiotherapy [4]. In particular, ionization chambers are affected by ion recombination effects, alt…

Alanine FLASH radiotherapy ultra-high dose rates EPR dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Dosimetric characterization of an ultra-high dose rate beam for FLASH radiotherapy through alanine EPR dosimetry

2022

Experimental evidence is growing, supporting the evidence of a considerable normal tissue sparing effect when treatments are delivered with dose rates much larger with respect to the conventional ones [1]. In particular, an increasing of the therapeutic window has been demonstrated for dose rates over 50 Gy/s, over a large variety of in-vivo experiments [2]. If confirmed, the ‘FLASH effect’ has the potential to re-shape the future of radiation treatments, with a significant impact on many oncology patients [3]. Ultra-high dose rate (UHDR) beams for FLASH radiotherapy present significant dosimetric challenges [4]. Ionization chambers are affected by ion recombination effects, although novel …

Alanine FLASH radiotherapy ultra-high dose rates EPR dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

FMECA Analyses of radiological over-exposure accident to patients in brachytherapy

2012

This paper presents safety analyses of accidental events which can involve patient during High Dose Rate brachytherapy treatment in over-exposures. The study has been performed by using the well-known techniques FMECA modified by Fuzzy logic theory. Moreover, fuzzy HEART methodology was employed in order to evaluate human error probabilities for each treatment stage. The obtained results, aimed to obtain a list of the deviations with a reasonable probability to produce significant adverse outcomes, provided some recommendations for procedures and safety equipments to reduce the occurrence of radiological over-exposure accidents.

Settore ING-IND/20 - Misure E Strumentazione NucleariSettore ING-IND/19 - Impianti NucleariHigh Dose Rate radiation therapy radiological risk FMECA fuzzy RPN
researchProduct